 Bulletin PD-20620 rev. C 08/01
30EPH06
Hyperfast Rectifier
Features
* * * * * Hyperfastfast Recovery Time Low Forward Voltage Drop Low Leakage Current 175C Operating Junction Temperature Single Diode Center Tap
trr = 28ns typ. IF(AV) = 30Amp VR = 600V
Description/ Applications State of the art Hyperfast recovery rectifiers designed with optimized performance of forward voltage drop, Hyperfast recover time, and soft recovery. The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in PFC Boost stage in the AC-DC section of SMPS, inverters or as freewheeling diodes. The IR extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers.
Absolute Maximum Ratings Parameters
VRRM IF(AV) IFSM TJ, TSTG Peak Repetitive Reverse Voltage Average Rectifier Forward Current Non Repetitive Peak Surge Current @ TC = 116C @ TJ = 25C
Max
600 30 300 - 65 to 175
Units
V A C
Operating Junction and Storage Temperatures
Case Styles 30EPH06
BASE COMMON CATHODE 2
1 CATHODE
3 ANODE
TO247
www.irf.com
1
30EPH06
Bulletin PD-20620 rev. C 08/01
Electrical Characteristics @ TJ = 25C (unless otherwise specified)
Parameters
VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage
Min Typ Max Units Test Conditions
600 2.0 2.6 V V V A A pF nH IR = 100A IF = 30A, TJ = 25C IF = 30A, TJ = 150C VR = VR Rated TJ = 150C, VR = VR Rated VR = 600V Measured lead to lead 5mm from package body
1.34 1.75 0.3 60 33 3.5 50 500 -
IR
Reverse Leakage Current
-
CT LS
Junction Capacitance Series Inductance
-
Dynamic Recovery Characteristics @ TJ = 25C (unless otherwise specified)
Parameters
trr Reverse Recovery Time
Min Typ Max Units Test Conditions
28 31 77 35 nC A ns IF = 1.0A, diF/dt = 50A/s, VR = 30V TJ = 25C TJ = 125C TJ = 25C TJ = 125C TJ = 25C TJ = 125C IF = 30A VR = 200V diF /dt = 200A/s
IRRM
Peak Recovery Current
-
3.5 7.7 65 345
Qrr
Reverse Recovery Charge
-
Thermal - Mechanical Characteristics
Parameters
TJ TStg RthJC RthJA ! RthCS" Wt Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Thermal Resistance, Junction to Ambient Thermal Resistance, Case to Heatsink Weight Per Leg Per Leg
Min
- 65 - 65 -
Typ
0.5 0.4 6.0 0.22 -
Max
175 175 0.9 70 12 10
Units
C
C/W
g (oz) Kg-cm lbf.in
Mounting Torque
6.0 5.0
! Typical Socket Mount "#Mounting Surface, Flat, Smooth and Greased
2
www.irf.com
30EPH06
Bulletin PD-20620 rev. C 08/01
1000
Reverse Current - I R (A)
1000 100 10 1 0.1
Tj = 175C 150C 125C 100C
25C
Instantaneous Forward Current - I F (A)
0.01 0.001
100
0.0001 0 100 200 300 400 500 600
Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage
1000
10
T = 175C J T = 150C J T = 25C J
Junction Capacitance - C T (pF)
T J = 25C
100
1 0 0.5 1 1.5 2 2.5 3 3.5
Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics
10 0 100 200 300 400 500 600
Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage
1
Thermal Impedance Z thJC (C/W)
0.1
D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01
PDM
t1
0.01
Single Pulse (Thermal Resistance)
t2
Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc
0.001 0.00001
0.0001 0.001 0.01 0.1 t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
1
10
www.irf.com
3
30EPH06
Bulletin PD-20620 rev. C 08/01
180
Allowable Case Temperature (C)
90
Average Power Loss ( Watts )
80 70 60 50 40 30 20 10 0 0
RMS Limit
160
DC
140 120
Square wave (D = 0.50) Rated Vr applied
DC D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5
100
see note (3)
80 0 5 10 15 20 25 30 35 40 45
Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current
5 10 15 20 25 30 35 40 45 Average Forward Current - IF(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
90 80 70 60 50 40 30 20
Qrr ( nC ) trr ( ns )
IF = 30 A IF = 15 A
1200
V R = 200V T J = 125C T J = 25C
1000
IF = 30 A IF = 15 A
800
600
400
200
10 0 100
V R = 200V T J = 125C T J = 25C
1000
di F /dt (A/s )
0 100
1000
Fig. 7 - Typical Reverse Recovery vs. di F /dt
di F /dt (A/s ) Fig. 8 - Typical Stored Charge vs. di F /dt
(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR
4
www.irf.com
30EPH06
Bulletin PD-20620 rev. C 08/01
Reverse Recovery Circuit
VR = 200V
0.01 L = 70H D.U.T.
diF /dt dif/dt ADJUST
D G IRFP250 S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
IF 0
trr ta tb
4
2
Q rr I RRM
0.5 I RRM di(rec)M/dt 0.75 I RRM
5
1
diF /dt f
1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
30EPH06
Bulletin PD-20620 rev. C 08/01
Outline Table
15.90 (0.626) 15.30 (0.602) 3.65 (0.144) DIA. 3.55 (0.139) 5.30 (0.209) 4.70 (0.185) 2.5 (0.098) 1.5 (0.059) 5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) 1 3 5.50 (0.217) 4.50 (0.177) (2 PLCS.)
1 3 ANODE BASE COMMON CATHODE 2
14.80 (0.583) 14.20 (0.559) 4.30 (0.170) 3.70 (0.145) 2.20 (0.087) MAX. 0.80 (0.032) 0.40 (0.213) 2.40 (0.095) MAX.
CATHODE
1.40 (0.056) 1.00 (0.039) 10.94 (0.430) 10.86 (0.427)
Conforms to JEDEC Outline TO-247 Dimensions in millimeters and (inches)
Ordering Information Table
Device Code
30
1
E
2
P
3
H
4
06
5
1 2 3 4 5
-
Current Rating (30 = 30A) E P H = Single Diode = TO-247 = HyperFast Recovery
Voltage Rating (06 = 600V)
6
www.irf.com
30EPH06
Bulletin PD-20620 rev. C 08/01
Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information 08/01
www.irf.com
7


▲Up To Search▲   

 
Price & Availability of 30EPH06

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X